ARTICLES & RESOURCES
Explore materials, technologies, design, and manufacturing in the life sciences.
Raw Materials Used in In Vitro Diagnostics
In vitro diagnostics (IVDs) are essential tools in modern medicine, providing clinicians with crucial information for disease detection, monitoring, and management. The development of effective and reliable IVDs hinges upon the selection of raw materials, which influence the sensitivity, specificity, and overall performance of these tests. A wide range of biological, chemical, and other engineered materials enable the performance of IVDs, each contributing unique properties that ensure test reliability, accuracy, and regulatory compliance. In this article, we break down these categories of raw materials and explore their function and specific application.
Biological Materials
Biological materials are foundational in creating IVDs due to their specific interactions with target analytes. These materials include antibodies, antigens, recombinant proteins, enzymes, DNA/RNA probes and primers, and cell lines, each fulfilling essential roles in detecting, amplifying, and analyzing biomarkers associated with various diseases.
Cell lines are cultivated to produce biological materials, such as antibodies, antigens, and recombinant proteins, which are used in various assays. These living cells provide a controlled environment for the consistent production of biological reagents, and they serve as model systems for studying disease mechanisms in diagnostics and research applications.
Antibodies
Antibodies are proteins engineered to recognize and bind specific molecular targets, known as antigens. Monoclonal and polyclonal antibodies are commonly employed in immunoassays such as ELISA (Enzyme-Linked Immunosorbent Assay) and lateral flow tests, enabling the detection of pathogens, biomarkers, and disease-specific proteins. The choice between monoclonal and polyclonal antibodies can impact the assay's sensitivity and specificity, with monoclonal antibodies offering higher specificity due to their ability to bind to a single epitope.
Antigens
Antigens, typically proteins or peptides, trigger immune responses and are used in IVDs to detect antibodies specific to diseases or pathogens. Antigens help determine past or current infections in infectious disease diagnostics by indicating the immune system's response. The quality and purity of antigens are critical in ensuring accurate test results, as any variability can lead to false positives or negatives.
Recombinant Proteins
Advances in genetic engineering have made recombinant proteins essential in IVD manufacturing. Unlike natural proteins, recombinant proteins are produced with high consistency, purity, and structural control, making them ideal for tests requiring precision. These proteins are particularly valuable in immunoassays and molecular diagnostics, where consistent protein behavior is essential for reliable results.
Enzymes
Enzymes are biological catalysts used to amplify target signals in diagnostic assays. Commonly used enzymes like horseradish peroxidase (HRP), alkaline phosphatase (AP), and DNA polymerases play roles in generating measurable signals, enabling biochemical reactions, and amplifying nucleic acids in assays such as PCR (Polymerase Chain Reaction). These enzymes enhance the sensitivity of tests, allowing for the detection of low concentrations of target analytes.
DNA/RNA Probes and Primers
In molecular diagnostics, probes and primers are short sequences of nucleotides that bind to specific DNA or RNA regions. These components are important in PCR and other nucleic acid-based assays, enabling the selective amplification and detection of target genetic material. High-quality probes and primers are crucial for minimizing non-specific binding, which can otherwise lead to false-positive or negative results.
Chemical Reagents
Chemical reagents support the biochemical reactions that drive IVD functionality. These reagents enhance the test's accuracy, sensitivity, and specificity by maintaining optimal pH, stabilizing biological materials, and generating detectable signals.
Buffers and Salts
Buffers, such as phosphate-buffered saline (PBS) and sodium chloride, are used to maintain the pH and ionic strength needed for enzyme stability and reaction efficacy. Stable pH conditions are vital for accurate enzyme function and protein stability, as deviations can impact assay reliability.
Detergents
Detergents are used to solubilize proteins, disrupt cell membranes, and reduce non-specific binding in diagnostic assays. They enhance assay specificity by preventing unwanted interactions between biomolecules, which helps minimize background noise and improve signal clarity.
Substrates
Substrates are used to generate signals that can be visually or instrumentally detected. Chromogenic substrates produce colored products, fluorogenic substrates emit fluorescence, and chemiluminescent substrates produce light. The choice of substrate can significantly influence the sensitivity and dynamic range of the assay, impacting its clinical utility.
Stabilizers
Stabilizers protect sensitive biological reagents, such as antibodies and enzymes, from degradation during storage and use. Sugars and proteins are commonly used stabilizers that extend reagent shelf life, ensuring consistency in assay performance.
Dyes and Labels
Dyes and labels provide visual or detectable signals in IVDs. Fluorescent dyes, radioactive labels, and gold nanoparticles are among the commonly used labels, each chosen based on the assay's requirements for detection sensitivity, signal duration, and measurement method.
Polymers and Plastics
Polymers and plastics serve as the structural backbone of many IVD devices, providing durability, compatibility with biological reagents, and adaptability to complex shapes. The choice of polymer depends on properties such as biocompatibility, chemical resistance, and mechanical strength.
Microfluidic Devices
Microfluidic devices, often made from polymers like PDMS (Polydimethylsiloxane), COC (Cyclic Olefin Copolymer), and polycarbonate, are designed to handle small sample volumes with high precision. These polymers are transparent, chemically inert, and amenable to microfabrication, making them ideal for lab-on-a-chip devices used in point-of-care diagnostics.
Plastic Consumables
Plastic consumables, including polystyrene microtiter plates, polypropylene reaction tubes, and polycarbonate sample containers, are widely used in IVD assays. These consumables are chosen for their chemical compatibility, ease of sterilization, and ability to withstand repeated use without compromising assay performance.
Membranes
Membranes like nitrocellulose and nylon are integral to lateral flow assays. These membranes capture specific biomolecules (antibodies, antigens, or nucleic acids), enabling the rapid detection of target analytes in point-of-care settings.
Nanomaterials
Nanomaterials possess unique properties that enhance diagnostic tests' sensitivity, speed, and miniaturization. Their high surface area, enhanced reactivity, and optical properties enable new diagnostic capabilities and the creation of compact, portable devices.
Biosensors
Nanomaterials increase biosensor sensitivity and selectivity, enabling the detection of low concentrations of target analytes. Gold nanoparticles, magnetic nanoparticles, and quantum dots are commonly used to facilitate signal transduction and amplification in compact sensor designs.
Immunoassays
In immunoassays, nanomaterials improve signal generation and stability, facilitating faster, more sensitive detection of antigens or antibodies. Their small size and high surface-to-volume ratio allow better interaction with target molecules, enhancing assay efficiency.
Nucleic Acid Detection
Nanomaterials improve nucleic acid detection sensitivity in assays like PCR. Their conductive and optical properties make them suitable for creating portable devices capable of rapid nucleic acid analysis, which is crucial in applications such as pathogen detection.
Lab-on-a-Chip Devices
Nanomaterials are used in lab-on-a-chip devices to fabricate microfluidic channels and functional components, enabling the integration of multiple diagnostic steps onto a single platform. This miniaturization facilitates faster processing times and lower sample requirements.
Julie Garlikov on point discussing improving the user experience in diagnostic testing.
Glassware and Silicone Materials
Glassware and silicon materials are essential in various IVD applications due to their optical transparency, chemical inertness, and durability.
Biosensors
Glass and silicon surfaces can be modified to immobilize biomolecules, such as antibodies, which are critical for biosensor functionality. They are also used in creating electrodes and optical waveguides for signal detection.
Microarrays
Glass slides provide a solid support for microarrays, enabling the simultaneous analysis of thousands of biomolecules. Surface modifications enhance the binding and hybridization of biomolecules, increasing the accuracy of these high-throughput assays.
Lab-on-a-Chip Devices
Glass and silicon are often used to fabricate microfluidic channels in lab-on-a-chip devices, allowing precise manipulation and analysis of samples. These materials offer compatibility with various analytical techniques and ensure device durability.
Flexible Materials
Flexible materials like nonwovens, membranes, and technical papers are integral to many IVD applications, providing filtration, absorption, and structural support. These materials are chosen based on their porosity, chemical resistance, and mechanical strength.
Glass Fiber
Glass fiber membranes are commonly used as filtration media in blood sample separation, effectively isolating plasma from blood cells for subsequent analysis.
Cellulose
Cellulose-based membranes and absorbent pads are widely used in lateral flow assays and sample purification due to their high absorbency and biocompatibility.
Nylon
Nylon membranes are used in lateral flow assays to capture biomolecules, providing a reliable platform for antibody-antigen interactions in point-of-care tests.
Adhesives and Sealants
Adhesives and sealants provide structural stability and ensure the proper function of IVD devices. These materials are selected based on their chemical compatibility, adhesion strength, and biocompatibility.
Pressure-sensitive Adhesives (PSAs)
PSAs are commonly used to bond layers in multilayer devices, such as microfluidic chips and lateral flow assays, allowing them to adhere to surfaces without additional activation.
Silicone Adhesives
Silicone-based adhesives are prized for their flexibility, durability, and moisture resistance, making them ideal for sealing IVD components.
UV-curable Adhesives
UV-curable adhesives offer rapid bonding and are often used in microfluidic devices, allowing precise control over the bonding process.
Hot Melt Adhesives
Hot melt adhesives are used for general-purpose bonding in IVD manufacturing, providing fast-setting adhesion that enhances production efficiency.
Electrochemical and Electronic Materials
Electrochemical and electronic materials are critical for detecting and measuring analytes in various diagnostic assays, especially biosensors and electrochemical immunoassays.
Electrodes and Electrolytes
Electrodes made of conductive materials like carbon, gold, platinum, and silver facilitate electron transfer in electrochemical assays, while electrolytes ensure current conduction. Reference electrodes, like Ag/AgCl, provide stable potentials essential for accurate measurements.
Printed Circuit Boards (PCBs) and Microcontrollers
PCBs and microcontrollers form the backbone of electronic IVD devices, facilitating signal processing and data acquisition. These components enable precise control over diagnostic operations, ensuring consistent test results.
Conclusion
Developing effective and reliable IVDs, which we cover in depth here, is a complex process requiring the careful selection and integration of various raw materials. Each category of materials - biological, chemical, polymers and plastics, nanomaterials, glass and silicone, flexible materials, adhesives and sealants, and electrochemical and electronic components - contributes distinct properties that influence the test's sensitivity, specificity, and stability. By understanding and leveraging these materials, developers of IVD tests can continue to innovate, improving diagnostic accuracy and expanding access to high-quality healthcare.
ARTICLES & RESOURCES